Medical Equipment, Medical Supplies & Medical Consumables
  • Register
  • Log In
  • Contact Us
0 items   |   $0.00
Full Catalogue Full Catalogue
  • HOME
  • Medical Equipment
  • 2nd Hand Equipment
  • Specials
  • Support
  • Company
  • Knowledge Base
Medical Equipment > Pulse Oximeters > 
Cart Summary
Your Basket is Empty
View Basket
Search
 
 
Navigation
Alcohol & Drug Testing
Audiometry
Autoclaves & Sterilisers
Bracing & Support
Blood Monitoring
Blood Pressure Monitors & Sphygmomanometers
Cryotherapy
Defibrillators
Diagnostic Equipment
Doctors Bag
Dopplers
ECGs
Electrosurgery
Emergency & Rescue
Fetal & Maternal Monitoring
Fridges
Furniture
Gas Equipment
Home Care & Rehabilitation
Hospital & Nursing Home
Syringe Pumps
Lights
Loupes & Headlights
Microscopes
Military
Nasal Measurement
Nebulisers
Opthalmic
Patient Monitoring
Podiatry Drills
Physiotherapy
Pulse Oximeters
Pulse Oximeter Accessories
Radiology
Resuscitation
Scales and Measurement
Spirometers
Suction & Irrigation
Ultrasound
Ultrasonic Cleaners
X-Ray
Womens Health
Visual Test Charts
Welch Allyn
Vein Finder
Products
M800-Hand-held-pulse-oximeter-spo2-web.jpg

Biolight M800 Handheld Pulse Oximeter- BIOM800KIT

Item Code: BIOM800KIT


$549.00 (Excl. GST)


Quantity:  
  • Description
  • Specification
  • Downloads
  • Video

BONUS 3 PROBES

Neonate
Pediatric
Adult

Biolight M800 Handheld Pulse Oximeter with Alarms

Auto rotation Hi-Res 2.4" colour OLED display: 320x240 pixels
SPO2 and PR monitoring (ECG optional)
Suitable for Adult, Pediatric & Neonatal patients
Spot check and continuous monitoring modes
Max 60,000 group short trend data store & review
16 hours of continuous SpO2 & ECG monitoring on 3 xAA alkaline (lithium battery optional)

Optional
3 Lead ECG Module & Cable
Lithium battery & Cradle
Carry Bag
Infrared Receiver to CPU
PC Software
Silicone Jacket
Disposable sensors for adult, pediatric & neonates

Safety standards
-SFDA classifilication : II
-CE classification : lib
-Type of protection against electric shock: II, with internal power device
- Degree of protection against electric shock: CF
- Degree of protection against ingress of liquid: IPX 1
- Equipment type: Handheld

Mechanical
- Dimension : 58.5mm(W)~t 1 23mm(H)~t28m m{O )
- Weight: <200g

Battery
-Type: 3AAAikaline batteries or
- Lithium ion rechargeable battery (Option}
-Runtime: > 16 hours for normal measurement status

Display
- 2.4H OLEO 320.240 pixels

Sound
-Gives audible alarm. button tone and beep tone
- Supports Pitch Tone and multi·level volume:
-Alarm tones meet the requirement of IEC 60601·1·8.

Data Storage
- Displaying way: Trend tabular
- Trend interval : 2 seconds to 30 minutes
-Trend parameter: PR, Sp02
-Trend data:Spot·checkmode: ID from 1 to 99. 300 group for each 10.
- Continuous monitor mode: 60000 group can be stored.
- Patient Range
-Adult, Pediatric and neonatal patients

BLT Dig ital Sp02
-Range: 0-100%
- Resolution: 1%
- Accuracy: 70% to 100%: ±2%
- 0% to 69%: unspecified
-Refreshing rate: <30 seconds
-Pitch Tone: with

PR
- Range: 25 bpm to 250 bpm
-Resolution: 1 bpm
- Accuracy: t2% or :t1 bpm, whichever is the greater
- Refreshing rate: <30 seconds
Nellcor Sp02 (Option)
... Range: 0% to 100%
- Re solution: 1%
- Accuracy: 70% to 100%: ±3%
... 0% to 69%: unspecified
- Refreshing rate:7 seconds
- Pitch Tone: with

PR
- Range: 20 bpm to 250 bpm
- Resolution: 1 bpm
-Accuracy: ± 3 bpm
- Refreshing rate: 7s

ECG (Option)
-Lead type: Standard: 3 lead (RA, LA. LL orR. L, F)
- Lead: 1, 2, 3
- Gain: 2.5mmlmV(•0.25). 5mmlmV(..:Q.5). 10mmlmV(>< 1)
- Input impedance: C:S.OMO
-Input current: <0.1 uA
-Baseline recovery: Monitor mode: s 3 s
-Electrode offset potential: ±500 mV d.c .
- ECG signal input range: · 6.0mV to +6.0mV
- CMRR: Diagnostic mode ii:89dB
- Monitor mode l:105dB
-Bandwidth (·3d B): Diagnostic mode: 0.05Hz to 1OOHz
-Monitor mode: 0.5Hz to 40Hz
-Standardizing signal: 1mV ±5%
- Electrode off indicating: with
- Work mode: Monitor and Diagnostic mode
- HR range: 10 bpm -300 bpm
- HR Resolution: 1 bpm
- HRAccuracy: t1% or ±1 bpm, whichever is the greater
- Protection: defibrillator proof
- Baseline recovery: <Ss after Defibrillation

Parameter :
- BLT Digital SP02, Pulse Rate. Pleth bar & Sp02 waveform.

Option
- Nellcor Sp02. 3·1ead ECG. infrared receiving adapter.
- Rechargeable lithium battery(include battery charger & AC-DC adapter).

Specifications subject to be changed without notice

Biolight-M800-Handheld-Pulse-Oximeter-Brochure

Consumables & Accessories

Related Products

C54.jpg

C54 Pulse Oximeter Child Size - CHOMD300C54

$99.00 (Excl. GST)

     
  • Products
  • Full Catalogue
  • Shopping Cart
  • Product Registration
  • Service Request
  • Remote Support
  • Delivery & Refund
  • Corporate Profile
  • Terms & Conditions
  • Privacy
  • Contact Us

copyright ©2012.
Zone Medical Pty Ltd
ABN 85 506 773 283

Facebook Twitter