Skip to main content

Sterrad NX 30 Litre Steriliser

$59,999.00 $9,999.00 Excl. GST

STERRAD NX System is an advanced hydrogen peroxide gas plasma unit that offers fast terminal sterilization with a standard 28-minute cycle time. Having only completed 2,000 Cycles this device is in excellent condition and runs perfectly. (Tested 8th May 2019 by an authorized national service agent.)

SKU: STERIL2H Category: Tag:
Product Description

Sterrad NX 30 Litre Steriliser with Mobile Trolley

The STERRAD NX Sterilisation System is an advanced hydrogen peroxide gas plasma system that offers fast terminal sterilization with a standard 28-minute cycle time and an advanced 38-minute cycle time.*

The system can sterilize a wide range of instruments, including single-channel flexible endoscopes, semi-rigid ureteroscopes, power drills, batteries, cameras, light cords, rigid scopes, general surgical instruments, and more. The system provides the flexibility of having dry, packaged, sterile instruments ready when needed.

The STERRAD NX System offers several unique features, including network connectivity, a diagnostics program, and an easy-to-read touch screen. Its compact size and simple plug-in make it ideal for placement in a variety of locations such as OR Substerile Rooms, OR Surgical Cores, Ambulatory Surgery Centers, Sterile Processing Departments and Specialty Departments, (e.g., Urology).

Only the STERRAD NX System provides all of this, enabling healthcare facilities to handle more caseloads, without delays, to keep the OR on schedule.

Sterrad NX Steriliser

Hydrogen Peroxide Gas Plasma Process

The STERRAD NX System involves the combined use of hydrogen peroxide and low-temperature gas plasma to safely and rapidly sterilize medical devices and materials without leaving any toxic residues. Hydrogen peroxide is an oxidizing agent that affects sterilization by oxidation of key cellular components.

Plasma is a state of matter distinguishable from a solid, liquid, or gas. Gas plasmas are highly ionized gases, composed of ions, electrons, and neutral particles that produce a visible glow. A solution of hydrogen peroxide and water (59% nominal peroxide by weight) is delivered to the sterilizer, concentrated to approximately 90%, vaporized and allowed to surround and interact with the devices to be sterilized.

Hydrogen peroxide is a bactericidal, virucidal, sporicidal, and fungicidal agent, even at low concentration and temperature. Applying a strong electrical field then creates plasma. The plasma breaks down the peroxide into a “cloud” of highly energized species that recombine, turning the hydrogen peroxide into water and oxygen.

Sterrad NX System Information

Hydrogen Peroxide (59% nominal weight)

Hydrogen Peroxide

  • Standard Cycle 28 Minutes
  • Advanced Cycle 38 Minutes

Water Vapor & Oxygen

Indications for Use

The STERRAD NX Sterilizer is designed for sterilization of both metal and nonmetal medical devices at low temperatures. The STERRAD sterilization process is a multi phase sterilization process that utilizes a combination of exposure to hydrogen peroxide vapor and plasma to affect sterilization. The STERRAD NX Sterilizer can sterilize instruments which have diffusion-restricted spaces, such as the hinged portion of forceps and scissors.

Medical devices with the following materials and dimensions can be processed in the STERRAD NX

Sterilizer Standard cycle:

  • Single-channel stainless steel lumens with an inside diameter of 1 mrn or larger and a length of 150 mm or shorter.
  • Single-channel stainless steel lumens with an inside diameter of 2 mm or larger and a length of 400 mm or shorter.

Medical devices, including most flexible endoscopes, with the following materials and dimensions can be processed in the STERRAD NX Sterilizer

Advanced cycle:

  • Single-channel stainless steel lumens with an inside diameter of 1 mm or larger and a length of 500 mrn or shorter.
  • Single-channel PEIPTFE flexible endoscopes with an inside diameter of 1 mm or larger and a length of 850 mm or shorter.
Specifications
Cycle Options
Standard: 28 minutes
Advanced: 38 minutes

Cycle Temperature
Less than 131°F / 55°C

Dimension
Sterilisation Unit Sterrad NX 30 Litre Specifications

System Only
Height: 33 inches
Width: 22 inches
Depth: 32 inches
Chamber Shape: Rectangular
Two-Tiered Shelf(wxD): 12.3 in x 23.6 in (46.4 x 50.2 x 14.6 cm)

System with Cart:
Height: 62.1 inches
Width: 24 inches
Depth: 35 inches

Electrical Requirements
Connections: 108-132 VAC 20A dedicated NEMA 5-20 receptacle to supply 16A continuous and 40A momentary current. Sharing current-carrying conductors (hot and/or neutral) is not allowed.
Placement: ASP recommends mounting the STERRAD® NX® System on the specially designed cart, product code 10300. The STERRAD® NX® System may be mounted on a countertop meeting specifications.

Operational Environment
Temperature: 64°F to 95°F/18°C to 35°C
Humidity: 10% to 85% up to 86°F ambient and linearly decreasing from 85% at 86°F to 70% at 95°F.
Downloads Additional Information

Additional Information

Weight30 kg
Dimensions85 × 85 × 60 cm

Sign up to receive the latest deals