Northern Hospital Patient Monitor – Gemini

$4,199.00$6,349.00 Excl. GST

The Gemini has been specifically designed for operating under an anesthesia environment. The fanless design makes for a super quiet environment, prevents dust collection and reduces the risk of airborne contamination. It features full touch screen control with switchable screen sizes. Suitable for adult, pediatric and neonate patients. BIS/NMT/EtCo2 optional.

Clear
SKU: NGE Category: Tag:
Northern Logo

Hospital Patient Monitor – Gemini

Hospital patient monitor features:

• 15.6” colour TFT LCD Touch Screen
• Suitable for adult, pediatric & neonatal patients
• Flexible parameters configuration for different clinical environments
• Screen Upgradeable To 17″ & 19″ Screen Post Purchase
• Standard Configuration 3 Lead ECG, HR, RESP, NIBP, Spo2, 2 Temp, PR
• Accurate Alarming System
• Up To 10 Waveform Display
• Pacemaker Detection
• ST & Arrhythmia Analysis
• Multi Selectable Screen Options
• 8 Hours holographic waveform review
• 168 hour graphical & tabular trend review with customisable size & colour settings
• Rechargeable high capacity Li-ion battery

Optional
• Thermal Printer, Trolley, Wall Mount, Masimo/Nellcor SpO2, Dual IBP, Mainstream/Sidestream EtCO2, Multigas, BIS, NMT, 12 Lead ECG, Cardiac Output, Wifi, 3G/4G Wireless Connection, Central Monitoring System

2 Year Warranty

Kit_Content_Patient Monitor_GEMINI
Display
15.6"color TFT screen
Resolution: 1366.768 dpi
Number of traces: 12 waveforms

Indicator
Power indicator light
Battery indicator light

Battery
Rechargeable lithium battery

I/0
LAN: 1 standard RJ45 Port
WLAN: IEEE802.11 b/g/n
USB: 2 USB ccnnectors
SD: 1 SD card Socket
VGA: 1 standard cclor VGA monitor ccnnector
Output: 1 standard ccnnector for Nurse Call, Defib Sync Analog Output

Recorder (Optional)
Built-in, thermal dot array
Waveform: 3 channels
Paper width: 50mm
Print speed: 12.5 mm/s, 25mm/s, 50mm/s

EGG
Lead Type: 3-lead, 5-lead,12-lead
EGG waveform: 2 channels, 7 channels, 12 channels
Gain selection: x0.25, x0.5; x1; x2
Sweep speed: 6.25mm/s, 12.5mm/s, 25mrnls, 50mm/s
Filter: Diagnostic mode: 0.05-150Hz
Monitoring mode: 0.5-40 Hz
Surgery mode: 1-20Hz
Notch: 50Hz, 60Hz
Heart Rate range: Adult: 15-300bpm;
Pediatric/ Neonate: 15-350bpm;
Accuracy: ±1 bpm or ±1

Respiration
Method: Trans-thoracic impedance
Operation modes: Auto/ Manual
Measurement range: Adult: 0-120 bpm;
Neonate/Pediatric: 0-150 bpm
Apnea alarm delay: 1 Os, 15s, 20s, 25s, 30s, 35s, 40s
Apnea Alarm: Selectable
Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s

Sp02
Measurement range: 0-100%
Resolution: 1%
Accuracy: ±2% (70-100% AduiVPediatric);
±3% (70-100% Neonate);
0-69% unspecified
Refreshing rate: 1 s

Masimo Rainbow®
SP02(0ptional)
Accuracy: ±2% (70-100% AduiVPediatric, non-motion,low perfusion);
±3% (70-100% Neonate, non-motion);
±3% (70-100% motion);
0-69% unspecified
Other measurements: SpHb®, SpOC'", Spco®, SpMet®

Pulse Rate
Range: 0-254 bpm
Resolution: 1 bpm
Accuracy: ±3bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1 s

NIBP
Method: Automatic oscillometric
Operation modes: Manual/Auto/STAT
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range:
Range of systolic pressure:
Adult Mode - 40 -270 mmHg
Pediatric Mode - 40 -200 mmHg
Neonatal Mode - 40 -135 mmHg
Range of diastolic pressure: Adult Mode - 10 -210 mmHg
Pediatric Mode - 10 -150 mmHg
Neonatal Mode - 10-100 mmHg
Range of mean pressure:
Adult Mode - 20 - 230mmHg
Pediatric Mode - 20 - 165mmHg
Neonatal Mode - 20 -110mmHg
Accuracy: Max mean error: ±5 mmHg
Measurement Interval: 1 ,2,3,4,5, 10, 15,30,60,90, 120,180,240,480minutes
Over-pressure protection: Double safety protection
Cuff pressure range: 0-280 mmHg
Resolution: 1 mmHg

Temperature
Accuracy: ±0.1 'C or ±0.2 •F(without probe)
Measurement range: 0-50'C (32 to 122 •F)
Channel: Two-channels
Resolution: 0.1 'C
Parameters: T1 , T2 and TD

IBP (Optional)
Channel: 2-channel I 4-channel
Measurement types: Systolic, Diastolic, Mean
Range:OmmHg-300mmHg
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, whichever is greater (without sensor)
Sensitivity: 5uV/mmHgN
Impedance range: 300 to 3000

C.O. (Optional)
Method: Thermodilution
Range: C.O .. 0.1 to 20Umin
TB: 23 to 43'C
T1: Oto27'C
Accuracy: C.O.:±S% or ±0.1 Urn in, whichever is greater
TB, T1 : ±0.1'C (without sensor)

Phasein ISA SidestreamC02 (Optional)
Warm-up time: Full accuracy within 10 seconds
Sampling flow rate: 50ml/min (+/-10ml/min)
Accuracy: ± (0.2 % + 2 % of the reading)
Measurement Range: 0 -15%
Rise time: 200ms, typical at 50ml/min flow rate
Total response time: within 3 seccnds (with 2 m Nomoline
sampling line)
AWRR Range: 0-150bpm
AWRR Accuracy: ±1 breath

Phasein IRMA Mainstream C02 (Optional)
Measurement Range: 0 -15%
Warm-up time: Full accuracy within 10 seconds
Accuracy: ± (0.2 % + 2 % of the reading)
AWRR Range: 0-150bpm
AWRR Accuracy: ±1 breath

Phasein Multi-gas IRMA AX+Mainstream (Optional)
Gas: C02, N20,HAL, ISO, ENF, SEV, DES with automatic identification
Warm-up time: Full accuracy within 20 seconds for IRMA AX+
C02 Accuracy . 0-10%: ± (0.2 % + 2 % of the reading)
10-15%: ± (0.3% + 2% of the reading)
N20Accuracy: 0-100%,± (2% + 2% of the reading)
HAL, ISO, ENF: 0-8% ' ± (0.15 % +5 % of the reading)
SEV: 0-1 O"k ± (0.15 % +5 % of the reading)
DES:0-22%: ± (0.15 % +5 % of the reading)
Agent identification time:< 20s (typical < 10s)
AWRR range: 0-150bpm
AWRR accuracy: +/-1 bpm
Apnea time: 20s, 25s, 30s, 35s,40s

Operation Environment
Power AC 1 00-250V, 50/60Hz
Temperature 0-40'C
Humidity 15-85%
Patient Range Adult, Pediatric, Neonate
Brochures
Northern Meditec Patient Monitor Catalogue
Hospital Patient Monitor from Northern Meditec - Gemini Brochure

User Manuals
Hospital Patient Monitor from Northern Meditec - Gemini (Aries) Standard Operating Procedures

Additional Information

Weight5 kg
Dimensions45 × 45 × 39 cm