Northern Multiparameter Patient Monitor – Pisces

$2,499.00$4,847.00 Excl. GST

Clear

Frequently Purchased Together

Five-Stand Trolley

Printing Paper 50mm for Northern Meditec Patient Monitors

SKU: NPI Categories: ,
Northern
Product Description

Multipara Patient Monitor – Pisces

Multipara Patient Monitor Features:
• 12.1” colour TFT LCD Screen
• Suitable for adult, pediatric & neonatal patients
• Flexible parameters configuration for different clinical environments
• Standard Configuration 3 Lead ECG, HR, RESP, NIBP, Spo2, 2 Temp, PR
• Accurate Alarming System
• Big Font Mode
• 8 Hours holographic waveform review
• 120 hour graphical & tabular trend review with customisable size & colour settings
• Rechargeable high capacity Li-ion battery

Optional features
• Thermal printer, Trolley, Wall Mount, Skin Temp, Nellcor/Masimo SpO2, IBP, C.O, EtCO2, Multi Gas, BIS, NMT (TOF-Watch)

2 Year Warranty

Looking for a more economic option? Check our Anasthesia Patient Monitor – Virgo.

Kit Contents Specifications
Display
12.1" color TFT LCD touch Screen,resolution: 800 x 600
8 waveform display, 12-leads ECG display

I/O
LAN: 1 standard RJ45 port
WLAN: IEEE802.11 b/g/n
USB:2 USB connectors
SD: 1 SO card socket
Output:1 connector for nurse call, Defib sync analog output
VGA: 1 VGA external socket (optional)

ECG
Lead type :3-lead,S-Iead, 12-lead
ECG waveform:2 channels,7 channels, 12 channels
Display sensitivity:
2.5mm/mV (x0.25), 5mm/mV (x0.5), 1 Omm/mV (x 1.0),
20mm/mV (x2.0)
Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Bandwidth
Diagnostic mode: 0.05Hz-100Hz
Monitor mode: 0.5Hz-40Hz
Surgery mode: 1Hz-20Hz
Strong filter mode: 5Hz-20Hz
CMRR>100dB
Notch: 50/60Hz notch filter can be set to on or off
Different ial input impedance> SMO
Electrode polarization voltage range: ±400mV
Baseline recovery t ime<3s after defibrillation (in monitor and
surgery mode)
Calibration signa1:1 mV (peak - peak), accuracy ±3%

TEMP
Accuracy: ±0.1 C or ±0.2 C F (without probe )
Measurement range: 5-50'C( 41- 122' F )
Channel : Two channels
Resolution: 0.1 C
Parameters : T1,T2 and TO

RESP
Method:Trans-thoracic impedance
Operation modes: Auto/Manual
Measurement range: Adult:0- 120 bmp;
Neonate/Pediatric:0-150bpm
Apnea alarm delay:1 Os, 1Ss.20s,25s,30s,35s,40s
Apnea alarm: Selectable
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s

NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20-40s
Measurement type: Systolic, Diastolic,Mean
Measurement range {mmHg)

Range of Systolic pressure:
Adult 40-270
Pediatric 40-230
Neonatal 40-135

Range of Diastolic pressure:
Adult 10-210
Pediatric 10-150
Neonatal 10-95


Range of Mean pressure:
Measurement accuracy
Adult 20-230
Pediatric 20-165
Neonatal 20-105

Measurement accuracy
Maximum average error: ±5mmHg
Maximum standard deviation: 8mmHg
Resolution: 1 mmHg
lnterval:1,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480 minutes
Overpressure protection: Software and hardware,
double safety protection
Cuff pressure range: 0-280mmHg

Northern SpO2
Measurement range : 0·1 00%
Resolution: 1%
Accuracy: ±2% ( 70-100%, Adult/Ped iatric);
±3% { 70-100% , Neonate);
0 -69%,unspecified
Refreshing Rate: 1 s

Masimo SpO2
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2% { 70-100% , Adult/Pediatric,non-motion,low prelusion);
±3% { 70-100%, Neonate,non-motion);
±3% ( 70-100% , motion);
0-69%,unspecified
Refreshing Rate: 1s

Pulse Rate
Range: 30-254 bpm
Resolution: 1 bpm
Accuracy: ±2bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1s

IBP (Optional)
Channel:2-channel or 4-channel
ART: 0 to 300 mmHg
PA: -6 to 120 mmHg
CVP/RAP/LAP/ICP: -10 to 40 mmHg
Measurement range: P1/P2 -50 to 300 mmHg
Resolution:1 mmHg
Accuracy:
±2% or ± 1 mmHg, whichever is greater (without sensor)
Sensitivity: 5uV /mmHg/V
Impedance range: 300 to 3000

Phasein IRMA Sidestream CO2 (optional)
Warm-up time: Full accuracy within 10 seconds
Sampling flow rate: 50ml/min( +/-1 0/min)
Accuracy: 0-15% (±0.2% of the reading)
15-25%, unspecified
Measurement Range: 0 -25%
Rise time: 200ms,typical at 50ml/min flow rate
Total response time:
within 3 seconds(with 2m Momoline sampling line)
AWRR Range: 0-150bpm

Phasein IRMA Mainstream CO2
Measurement Range: 0 -25%
Warm-up time: Full accuracy within 10 seconds
Accuracy: 0-15% (±0.2% of the reading)
15-25%, unspecified
AWRR Range: 0-150bpm

C.O. (optional)
Method: Thermodilution
Range: C.O.: 0.2 to 20 L/min
TB: 23 to 45 ·c
T1 : -1 to 27C
Accuracy:C.O.:±5% or ±0.1 L/min, whichever is greater
TB, T1 : ±O5C (without sensor)


Recorder (optional)
Built-in, Thermal dot array
Horizontal resolution :16 dots/mm (25 mm/s paper speed)
Vertical resolution:8 dots/mm
Paper speed:25 mm/s, 50 mm/s
Number of waveform channels:3

Operating Environment
Power: AC-=250, 50/60Hz
Temperature:5-40C
Humidity: <80%
Patient Range: Adult, Pediatric, Neonate
Downloads Additional Information

Additional Information

Weight5 kg
Dimensions45 × 46 × 39 cm
Data Recording

Printer, None

ETC02

Respironics Sidestream, None

Accessories & Consumables