Anaesthesia Patient Monitor

Anaesthesia Patient Monitor

  • 12.1” colour TFT LCD Screen
  • Suitable for adult, pediatric & neonatal patients
  • Flexible parameters configuration for different clinical environments
  • Standard Configuration 3 Lead ECG, HR, RESP, NIBP, Spo2, 2 Temp, PR
  • Accurate Alarming System
  • Big Font Mode
  • 8 Hours holographic waveform review
  • 120 hour graphical & tabular trend review with customisable size & colour settings
  • Rechargeable high capacity Li-ion battery

Optional

  • Thermal printer, Trolley, Wall Mount, Skin Temp,

2 Year Warranty

Looking for a more advanced monitor? Check our Multipara Patient Monitor – Pisces.

Specifications

Display

  • 12.1″ color TFT screen
  • Resolution: 800*600 dpi
  • Number of traces: 8 waveforms

Indicator

  • Power indicator light
  • Battery indicator light

Battery

  • Rechargeable lithium battery

I/O

  • LAN: 1 standard RJ45 Port
  • WLAN: IEEE802.11 b/g/n
  • USB: 2 USB connectors
  • SO: 1 SO card Socket
  • VGA: 1 standard color VGA monitor connector
  • Output: 1 standard connector for Nurse Call, Defib Sync Analog Output

Recorder (Optional)

  • Built-in, thermal dot array
  • Waveform: 3 channels
  • Paper width: 50mm
  • Print speed: 12.5 mm/s, 25mm/s, 50mm/s

ECG

  • Lead Type: 3-lead, 5-lead, 12-lead
  • ECG waveform: 2 channels, 7 channels, 12 channels
  • Gain selection: x0.25, x0.5; x1; x2
  • Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
  • Filter: Diagnostic mode: 0.05-150Hz
  • Monitoring mode: 0.5-40 Hz
  • Surgery mode: 1-20Hz
  • Notch: 50Hz, 60Hz
  • Heart Rate range: Adult: 15-300bpm;
  • Pediatric/ Neonate: 15-350bpm;
  • Accuracy: ±1 bpm or ±1 %, whichever is greater
  • Resolution: ±1 bpm

Respiration

  • Method: Trans-thoracic impedance
  • Operation modes: Auto/ Manual
  • Measurement range: Adult: 0-120 bpm;
  • Neonate/Pediatric: 0-150 bpm
  • Apnea alarm delay: 1 Os, 15s, 20s, 25s, 30s, 35s, 40s
  • Apnea Alarm: Selectable
  • Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s

Sp02

  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy: ±2% (70-100% Adult/Pediatric); ±3% (70-100% Neonate); 0-69% unspecified
  • Refreshing rate: 1s

Masimo SET®

  • SP02(0ptional)
  • Accuracy: ±2% (70-100% Adult/Pediatric, non-motion,low perfusion); ±3% (70-100% Neonate, non-motion); ±3% (70-100% motion); 0-69% unspecified

Pulse Rate

  • Range: 0-254 bpm
  • Resolution: 1 bpm
  • Accuracy: ±3bpm (non-motion) ±5bpm (motion)
  • Refreshing rate: 1s

NIBP

  • Method: Automatic oscillometric
  • Operation modes: Manual/Auto I STAT
  • Measurement unit: mmHg/kPa selectable
  • Measurement types: Systolic, Diastolic, Mean
  • Measurement range:
    • Range of systolic pressure:
      • Adult Mode 40-270 mmHg
      • Pediatric Mode 40-200 mmHg
      • Neonatal Mode 40 – 135 mmHg
    • Range of diastolic pressure:
      • Adult Mode 10-210 mmHg
      • Pediatric Mode 10 – 150 mmHg
      • Neonatal Mode 10-100 mmHg
    • Range of mean pressure:
      • Adult Mode 20- 230mmHg
      • Pediatric Mode 20- 165mmHg
      • Neonatal Mode 20- 110mmHg
  • Accuracy: Max mean error: ±5 mmHg
  • Measurement Interval: 1 , 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480minutes
  • Over-pressure protection: Double safety protection
  • Cuff pressure range: 0-280 mmHg
  • Resolution: 1 mmHg

Temperature

  • Accuracy: ±0.1 “C or ±0.2 “F (without probe)
  • Measurement range: 0-50″C (32 to 122 “F)
  • Channel: Two-channels
  • Resolution: 0.1 “C
  • Parameters: T1 , T2 and TD

IBP (Optional)

  • Channel: 2-channel
  • Measurement types: Systolic, Diastolic, Mean
  • Range:OmmHg-300mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2% or ±1 mmHg, whichever is greater (without sensor)
  • Sensitivity: 5uV/mmHgN
  • Impedance range: 300 to 3000

Operation Environment

  • Power: AC100-250V, 50/60Hz
  • Temperature: 0 -40″C
  • Humidity: 15-85%
  • Patient Range: Adult, Pediatric, Neonate

Videos

Reviews
Be the first to review “Northern Virgo Patient Monitor”

Your email address will not be published. Required fields are marked *

There are no reviews yet.

Product Enquiry
Have an enquiry relating to this product?
Get in touch today!

Fill out the form and one of our team will be in touch with you in regards to your enquiry. Alternatively you can give us a call on:

This field is for validation purposes and should be left unchanged.
LOADING...

Select Your Login Type

Customer Login

Distributor Login

Share This

Select your desired option below to share a direct link to this page.
Your friends or family will thank you later.