The Northern Aquarius Vital Sign Monitor is an entry-level Patient Monitor at an extremely affordable price. Intuitive touchscreen navigation and monitoring of the patient’s vital signs including SpO2, NIBP and Heart Rate with Li-ion battery (10 hours).  This monitor is suitable for outpatient departments, spot checks, transport, ward and other basic monitoring.

Product Description

Vital Signs Monitor from Northern Meditec

Features:
• 8” colour TFT LCD Touchscreen
• Portable, ergonomic, light weight, sturdy design
• Suitable for adult, pediatric & neonatal patients
• Flexible parameters configuration for different clinical environments
• Spot-check and continuous monitoring mode with alarms
• Graphical & tabular trend review with customisable size & colour settings
• Rechargeable Li-ion Battery (up to 10 hours)
• 48 hours holographic wave review for each patient
• Wired or Wireless CMS (Central Monitoring System)

Optional
• Thermal printer, Trolley, Wall Mount, ECG, Quick Temp, EtCO2, Multigas, Nellcor/Masimo SpO2, Bar Code Scan
• Wired or Wireless CMS (Central Monitoring System)

*Stand not included

2 Year Warranty

Looking for a Monitor with ECG as a standard option? Check our Vitals Monitor Aquarius Plus.

Specifications

Display
8” color TFT LCD Screen,relosution:800 x 600

ECG (optional)
Lead type
3-lead:l, II, Ill
S· lead:l, II, lll,aVR, a VI., aVF, V

Display sensitivity:
2.5mm;mv (x0.25), Smm;mv (x0.5), 10mm;mv (x1.0),
20mm;mv {x2.0)
Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

Bandwidth
Diagnostic mode: 0.05Hz-100Hz
Monitor mode: 0.5Hz-40Hz
Surgery mode: 1Hz-20Hz
Strong filter mode: 5Hz-20Hz

CMRR>100dB
Notch: 50/60Hz notch filter can be set to on or off
Differential input impedance> SMO
Electrode polarization voltage range: ±400mV
Baseline recovery time<3s after defibrillation {in moni tor and
surgery mode)
Calibration signal:1mV (peak – peak), accuracy ±3%

RESP
Measurement method : Thoracic electrical bio1 pedance
Measuring lead: Lead I, II
Wave gain: x0.25, xO.S, x 1, x2
Respiratory impedance range: 0.5 ·50
Baseline impedance: 500-40000
Gain: 10 grades
Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s

TEMP
Measurement method: Thermistor
Measuring range: 5- SO’C (41-122’F)
Resolution: 0.1’C
Measurement accuracy: ±0.1’C

Printing (optional)
Built-in,Thermal dot array
Horizontal resolution :16 dots/mm (25 mm/s paper speed)
Vertical resolution:8 dots/mm
Paper speed:25 mm/s, 50 mm/s
Number of waveform channels:3

NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20-40s
Measurement type: Systolic, Diastolic,Mean
Measurement range {mmHg)

Range of Systolic pressure:
Adult 40-270
Pediatric 40-230
Neonatal 40-135

Range of Diastolic pressure:
Adult 10-210
Pediatric 10-150
Neonatal 10-100

Range of Mean pressure:
Measurement accuracy
Adult 20-230
Pediatric 20-165
Neonatal 20-110

Maximum average error: ±SmmHg
Maximum standard deviation: 8mmHg
Resolution: 1 mmHg
lnterval:1 ,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480minutes
Overpressure protection: Software and hardware,double
safety protection
Cuff pressure range: 0-280mmHg

Northern SpO2
Measurement range : 0·1 00%
Resolution: 1%
Accuracy: ±2% ( 70-100%, Adult/Ped iatric);
±3% { 70-100% , Neonate);
0 -69%,unspecified
Refreshing Rate: 1 s

Masimo SpO2 (optional)
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2% { 70-100% , Adult/Pediatric,non-motion,low prelusion);
±3% { 70-100%, Neonate,non-motion);
±3% ( 70-100% , motion);
0-69%,unspecified
Refreshing Rate: 1

Infrared Ear thermometer (optional)
Diplayed range: 34- 42.2’C {93.2-108 F’)
Operation ambient temperature range: 10-40’C{ 50-104’F)
Accuracy for displayed temerature range:
~35’C{ 95.9’F) -s42.2’C{ 107.6’F) range ±0.2’C{ 0.4’F)
< 35’C ( 95.9’F ) – ~34’C { 93.2’F) range ±0.3’C{ O.S’F)

Phasein IRMA Sidestream CO2 (optional)
Warm·up time: Full accuracy within 10 seconds
Sampling flow rate: SOml/min(+/·10/min)
Accuracy:±(0.2%+2% of the reading)
Measurement Range: 0 ·15%
Rise time: 200ms,typical at SOml/min flow rate
Total response time:
within 3 seconds(with 2m Momoline sampling line)
AWRR Range: 0·150bpm
AWRR Accuracy:±1 breath

Phasein IRMA Mainstream CO2 (optional)
Measurement Range: 0 ·15%
Warm-up time: Full accuracy within 10 seconds
Accuracy:±(0.2%+2% of the reading}
AWRR Range: 0-150bpm
AWRR Accuracy·+ 1 breath

Operating Environment
Phasein IRMA Mainstream CO2
Power: AC-=250, 50/60Hz
Temperature: 0-40C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate

Videos

Reviews
Be the first to review “Northern Aquarius Vital Signs Monitor with Touchscreen”

Your email address will not be published. Required fields are marked *

There are no reviews yet.

Product Enquiry
Have an enquiry relating to this product?
Get in touch today!

Fill out the form and one of our team will be in touch with you in regards to your enquiry. Alternatively you can give us a call on:

This field is for validation purposes and should be left unchanged.
LOADING...

Select Your Login Type

Customer Login

Distributor Login

Share This

Select your desired option below to share a direct link to this page.
Your friends or family will thank you later.