Display
- 15.6″color TFT screen
- Resolution: 1366.768 dpi
- Number of traces: 12 waveforms
Indicator
- Power indicator light
- Battery indicator light
Battery
- Rechargeable lithium battery
I/0
- LAN: 1 standard RJ45 Port
- WLAN: IEEE802.11 b/g/n
- USB: 2 USB ccnnectors
- SD: 1 SD card Socket
- VGA: 1 standard cclor VGA monitor ccnnector
- Output: 1 standard ccnnector for Nurse Call, Defib Sync Analog Output
Recorder (Optional)
- Built-in, thermal dot array
- Waveform: 3 channels
- Paper width: 50mm
- Print speed: 12.5 mm/s, 25mm/s, 50mm/s
EGG
- Lead Type: 3-lead, 5-lead,12-lead
- EGG waveform: 2 channels, 7 channels, 12 channels
- Gain selection: x0.25, x0.5; x1; x2
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mrnls, 50mm/s
- Filter: Diagnostic mode: 0.05-150Hz
- Monitoring mode: 0.5-40 Hz
- Surgery mode: 1-20Hz
- Notch: 50Hz, 60Hz
- Heart Rate range: Adult: 15-300bpm;
- Pediatric/ Neonate: 15-350bpm;
Accuracy: ±1 bpm or ±1
Respiration
- Method: Trans-thoracic impedance
- Operation modes: Auto/ Manual
- Measurement range: Adult: 0-120 bpm;
- Neonate/Pediatric: 0-150 bpm
- Apnea alarm delay: 1 Os, 15s, 20s, 25s, 30s, 35s, 40s
- Apnea Alarm: Selectable
- Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s
Sp02
- Measurement range: 0-100%
- Resolution: 1%
- Accuracy: ±2% (70-100% AduiVPediatric);
±3% (70-100% Neonate);
0-69% unspecified
- Refreshing rate: 1 s
Masimo Rainbow®
- SP02(0ptional)
- Accuracy: ±2% (70-100% AduiVPediatric, non-motion,low perfusion);
±3% (70-100% Neonate, non-motion);
±3% (70-100% motion);
0-69% unspecified
- Other measurements: SpHb®, SpOC'”, Spco®, SpMet®
Pulse Rate
- Range: 0-254 bpm
- Resolution: 1 bpm
- Accuracy: ±3bpm (non-motion)
±5bpm (motion)
- Refreshing rate: 1 s
NIBP
- Method: Automatic oscillometric
- Operation modes: Manual/Auto/STAT
- Measurement unit: mmHg/kPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range:
- Range of systolic pressure:
- Adult Mode – 40 -270 mmHg
- Pediatric Mode – 40 -200 mmHg
- Neonatal Mode – 40 -135 mmHg
- Range of diastolic pressure: Adult Mode – 10 -210 mmHg
- Pediatric Mode – 10 -150 mmHg
- Neonatal Mode – 10-100 mmHg
- Range of mean pressure:
- Adult Mode – 20 – 230mmHg
- Pediatric Mode – 20 – 165mmHg
- Neonatal Mode – 20 -110mmHg
- Accuracy: Max mean error: ±5 mmHg
- Measurement Interval: 1 ,2,3,4,5, 10, 15,30,60,90, 120,180,240,480minutes
- Over-pressure protection: Double safety protection
- Cuff pressure range: 0-280 mmHg
- Resolution: 1 mmHg
Temperature
- Accuracy: ±0.1 ‘C or ±0.2 •F(without probe)
- Measurement range: 0-50’C (32 to 122 •F)
- Channel: Two-channels
- Resolution: 0.1 ‘C
- Parameters: T1 , T2 and TD
IBP (Optional)
- Channel: 2-channel I 4-channel
- Measurement types: Systolic, Diastolic, Mean
- Range:OmmHg-300mmHg
- Resolution: 1 mmHg
- Accuracy: ±2% or ±1mmHg, whichever is greater (without sensor)
- Sensitivity: 5uV/mmHgN
- Impedance range: 300 to 3000
C.O. (Optional)
- Method: Thermodilution
- Range: C.O .. 0.1 to 20Umin
- TB: 23 to 43’C
- T1: Oto27’C
- Accuracy: C.O.:±S% or ±0.1 Urn in, whichever is greater
- TB, T1 : ±0.1’C (without sensor)
Phasein ISA SidestreamC02 (Optional)
- Warm-up time: Full accuracy within 10 seconds
- Sampling flow rate: 50ml/min (+/-10ml/min)
- Accuracy: ± (0.2 % + 2 % of the reading)
- Measurement Range: 0 -15%
- Rise time: 200ms, typical at 50ml/min flow rate
- Total response time: within 3 seccnds (with 2 m Nomoline
sampling line)
- AWRR Range: 0-150bpm
- AWRR Accuracy: ±1 breath
Phasein IRMA Mainstream C02 (Optional)
- Measurement Range: 0 -15%
- Warm-up time: Full accuracy within 10 seconds
- Accuracy: ± (0.2 % + 2 % of the reading)
- AWRR Range: 0-150bpm
- AWRR Accuracy: ±1 breath
Phasein Multi-gas IRMA AX+Mainstream (Optional)
- Gas: C02, N20,HAL, ISO, ENF, SEV, DES with automatic identification
- Warm-up time: Full accuracy within 20 seconds for IRMA AX+
- C02 Accuracy . 0-10%: ± (0.2 % + 2 % of the reading)
10-15%: ± (0.3% + 2% of the reading)
- N20Accuracy: 0-100%,± (2% + 2% of the reading)
HAL, ISO, ENF: 0-8% ‘ ± (0.15 % +5 % of the reading)
SEV: 0-1 O”k ± (0.15 % +5 % of the reading)
DES:0-22%: ± (0.15 % +5 % of the reading)
- Agent identification time:< 20s (typical < 10s)
- AWRR range: 0-150bpm
- AWRR accuracy: +/-1 bpm
- Apnea time: 20s, 25s, 30s, 35s,40s
Operation Environment
- Power AC 1 00-250V, 50/60Hz
- Temperature 0-40’C
- Humidity 15-85%
- Patient Range Adult, Pediatric, Neonate