Northern Pisces Multiparameter Patient Monitor

$2,999.00

Arriving Soon
[woocommerce_humm_elementor]

The Northern Pisces Patient Monitor has flexible parameter configuration for different clinical environments. Standard Configuration includes 3 Lead ECG, HR, RESP, NIBP, Spo2, 2 Temp, PR with the ability to configure or add additional parameters such as Masimo/Nellcor SpO2, Dual IBP, Mainstream/Sidestream EtCO2, Multigas, BIS, NMT, 12 Lead ECG.

Optional printer and EtCo2 available.

Product Description

Multipara Patient Monitor – Pisces

Multipara Patient Monitor Features:

  • 12.1” colour TFT LCD Screen
  • Suitable for adult, pediatric & neonatal patients
  • Flexible parameters configuration for different clinical environments
  • Standard Configuration 3 Lead ECG, HR, RESP, NIBP, Spo2, 2 Temp, PR
  • Accurate Alarming System
  • Big Font Mode
  • 8 Hours holographic waveform review
  • 120 hour graphical & tabular trend review with customisable size & colour settings
  • Rechargeable high capacity Li-ion battery

Optional features

  • Thermal printer, Trolley, Wall Mount, Skin Temp, Nellcor/Masimo SpO2, IBP, C.O, EtCO2, Multi Gas, BIS, NMT (TOF-Watch)

2 Year Warranty

Looking for a more economic option? Check our Anasthesia Patient Monitor – Virgo.

Specifications

Display

  • 12.1″ color TFT LCD touch Screen,resolution: 800 x 600
  • 8 waveform display, 12-leads ECG display

I/O

  • LAN: 1 standard RJ45 port
  • WLAN: IEEE802.11 b/g/n
  • USB:2 USB connectors
  • SD: 1 SO card socket
  • Output:1 connector for nurse call, Defib sync analog output
  • VGA: 1 VGA external socket (optional)

ECG

  • Lead type :3-lead,S-Iead, 12-lead
  • ECG waveform:2 channels,7 channels, 12 channels
  • Display sensitivity:
    • 2.5mm/mV (x0.25), 5mm/mV (x0.5), 1 Omm/mV (x 1.0), 20mm/mV (x2.0)
  • Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
  • Bandwidth
    • Diagnostic mode: 0.05Hz-100Hz
    • Monitor mode: 0.5Hz-40Hz
    • Surgery mode: 1Hz-20Hz
    • Strong filter mode: 5Hz-20Hz
    • CMRR>100dB
  • Notch: 50/60Hz notch filter can be set to on or off
  • Differential input impedance> SMO
  • Electrode polarization voltage range: ±400mV
  • Baseline recovery time<3s after defibrillation (in monitor and surgery mode)
  • Calibration signa1:1 mV (peak – peak), accuracy ±3%

TEMP

  • Accuracy: ±0.1 C or ±0.2 C F (without probe )
  • Measurement range: 5-50’C( 41- 122′ F )
  • Channel : Two channels
  • Resolution: 0.1 C
  • Parameters : T1,T2 and TO

RESP

  • Method:Trans-thoracic impedance
  • Operation modes: Auto/Manual
  • Measurement range: Adult:0- 120 bmp;
  • Neonate/Pediatric:0-150bpm
  • Apnea alarm delay:1 Os, 1Ss.20s,25s,30s,35s,40s
  • Apnea alarm: Selectable
  • Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s

NIBP

  • Measurement method : Automatic oscillometric method
  • Operating mode:Manual, automatic, continuous
  • Measurement unit: mmHg/kPa selectable
  • Typical measurement time: 20-40s
  • Measurement type: Systolic, Diastolic, Mean
  • Measurement range {mmHg)

Range of Systolic pressure:

  • Adult 40-270
  • Pediatric 40-230
  • Neonatal 40-135

Range of Diastolic pressure:

  • Adult 10-210
  • Pediatric 10-150
  • Neonatal 10-95

Range of Mean pressure:

  • Measurement accuracy
    • Adult 20-230
    • Pediatric 20-165
    • Neonatal 20-105

Measurement accuracy

  • Maximum average error: ±5mmHg
  • Maximum standard deviation: 8mmHg
  • Resolution: 1 mmHg
  • lnterval:1,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480 minutes
  • Overpressure protection: Software and hardware, double safety protection
  • Cuff pressure range: 0-280mmHg

Northern SpO2

  • Measurement range : 0·1 00%
  • Resolution: 1%
  • Accuracy: ±2% ( 70-100%, Adult/Ped iatric);
    • ±3% { 70-100% , Neonate);
    • 0 -69%,unspecified
  • Refreshing Rate: 1 s

Masimo SpO2

  • Measurement range : 0-100%
  • Resolution: 1%
    Accuracy:

    • ±2% { 70-100% , Adult/Pediatric,non-motion,low prelusion);
    • ±3% { 70-100%, Neonate,non-motion);
    • ±3% ( 70-100% , motion);
    • 0-69%,unspecified
  • Refreshing Rate: 1s

Pulse Rate

  • Range: 30-254 bpm
  • Resolution: 1 bpm
  • Accuracy: ±2bpm (non-motion) ±5bpm (motion)
  • Refreshing rate: 1s

IBP (Optional)

  • Channel:2-channel or 4-channel
  • ART: 0 to 300 mmHg
  • PA: -6 to 120 mmHg
  • CVP/RAP/LAP/ICP: -10 to 40 mmHg
  • Measurement range: P1/P2 -50 to 300 mmHg
  • Resolution:1 mmHg
  • Accuracy: ±2% or ± 1 mmHg, whichever is greater (without sensor)
  • Sensitivity: 5uV /mmHg/V
  • Impedance range: 300 to 3000

Phasein IRMA Sidestream CO2 (optional)

  • Warm-up time: Full accuracy within 10 seconds
  • Sampling flow rate: 50ml/min( +/-1 0/min)
  • Accuracy: 0-15% (±0.2% of the reading) 15-25%, unspecified
  • Measurement Range: 0 -25%
  • Rise time: 200ms,typical at 50ml/min flow rate
  • Total response time: within 3 seconds(with 2m Momoline sampling line)
  • AWRR Range: 0-150bpm

Phasein IRMA Mainstream CO2

  • Measurement Range: 0 -25%
  • Warm-up time: Full accuracy within 10 seconds
  • Accuracy: 0-15% (±0.2% of the reading)
  • 15-25%, unspecified
  • AWRR Range: 0-150bpm

C.O. (optional)

  • Method: Thermodilution
  • Range: C.O.: 0.2 to 20 L/min
  • TB: 23 to 45 ·c
  • T1 : -1 to 27C
  • Accuracy:C.O.:±5% or ±0.1 L/min, whichever is greater
  • TB, T1 : ±O5C (without sensor)

Recorder (optional)

  • Built-in, Thermal dot array
  • Horizontal resolution :16 dots/mm (25 mm/s paper speed)
  • Vertical resolution:8 dots/mm
  • Paper speed:25 mm/s, 50 mm/s
  • Number of waveform channels: 3

Operating Environment

  • Power: AC-=250, 50/60Hz
  • Temperature:5-40C
  • Humidity: <80%
  • Patient Range: Adult, Pediatric, Neonate

Videos

Reviews
Be the first to review “Northern Pisces Multiparameter Patient Monitor”

Your email address will not be published. Required fields are marked *

There are no reviews yet.

Product Enquiry
Have an enquiry relating to this product?
Get in touch today!

Fill out the form and one of our team will be in touch with you in regards to your enquiry. Alternatively you can give us a call on:

This field is for validation purposes and should be left unchanged.
LOADING...

Select Your Login Type

Customer Login

Distributor Login

Share This

Select your desired option below to share a direct link to this page.
Your friends or family will thank you later.