Display
- 15.6″ color TFT screen
- Resolution: 1366*768 dpi
- Number of traces: 12 waveforms
Indicator
- Power indicator light
- Battery indicator light
Battery
- Rechargeable lithium battery
Networking Wired Or Wireless
I/O
- LAN: 1 standard RJ45 Port
- WLAN: IEEE802.11 b/g/n
- USB: 2 USB connectors
- SO: 1 SD card Socket
- VGA: 1 standard color VGA monitor connector
- Output: 1 standard connector for Nurse Call, Defib Sync Analog Output
Recorder (Optional)
- Built-in, thermal dot array
- Waveform: 3 channels
- Paper width: 50mm
- Print speed: 12.5 mm/s, 25mm/s, 50mm/s
ECG
- Lead Type: 3-lead, 5-lead, 12-lead
- ECG waveform: 2 channels, 7 channels, 12 channels
- Gain selection: x0.25, x0.5; x1; x2
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
- Filter: Diagnostic mode: 0.05-150Hz
- Monitoring mode: 0.5-40 Hz
- Surgery mode: 1-20Hz
- Notch: 50Hz, 60Hz
- Heart Rate range: Adult: 15-300bpm;
- Pediatric! Neonate: 15-350bpm;
- Accuracy: ±1 bpm or ±1 %, whichever is greater
- Resolution: ±1bpm
Respiration
- Method: Trans-thoracic impedance
- Operation modes: Auto/ Manual
- Measurement range: Adult: 0-120 bpm;
- Neonate/Pediatric: 0-150 bpm
- Apnea alarm delay: 1Os, 15s, 20s, 25s, 30s, 35s, 40s
- Apnea Alarm: Selectable
- Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s
Sp02
- Measurement range: 0-100%
- Resolution: 1%
- Accuracy: ±2% (70-100% Adult/Pediatric);
- ±3% (70-100% Neonate);
- 0-69% unspecified
- Refreshing rate: 1s
Masimo SET®
- SP02(0ptional)
- Accuracy: ±2% (70-100% Adult/Pediatric, non-motion,low perfusion);
- ±3% (70-100% Neonate, non-motion);
- ±3% (70-100% motion);
- 0-69% unspecified
Pulse Rate
- Range: 0-254 bpm
- Resolution: 1 bpm
- Accuracy: ±3bpm (non-motion)
- ±5bpm (motion)
- Refreshing rate: 1s
NIBP
- Method: Automatic oscillometric
- Operation modes: Manual/Auto I STAT
- Measurement unit: mmHg/kPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range:
- Range of systolic pressure:
- Adult Mode 40 -270 mmHg
- Pediatric Mode 40 – 200 mmHg
- Neonatal Mode 40 – 135 mmHg
- Range of diastolic pressure:
- Adult Mode 10 – 210 mmHg
- Pediatric Mode 10 – 150 mmHg
- Neonatal Mode 10 – 100 mmHg
- Range of mean pressure:
- Adult Mode 20- 230mmHg
- Pediatric Mode 20 – 165mmHg
- Neonatal Mode 20 – 110mmHg
- Accuracy: Max mean error: ±5 mmHg
- Measurement Interval: 1 ,2,3,4,5, 10, 15,30,60,90, 120,180,240,
480minutes
- Over-pressure protection: Double safety protection
- Cuff pressure range: 0-280 mmHg
- Resolution: 1 mmHg
Temperature
- Accuracy: ±0.1 “C or ±0.2 “F (without probe)
- Measurement range: 0-50″C (32 to 122 “F)
- Channel: Two-channels
- Resolution: 0.1 “C
- Parameters: T1 , T2 and TD
IBP (Optional)
- Channel: 2-channel
- Measurement types: Systolic, Diastolic, Mean
- Range:OmmHg-300mmHg
- Resolution: 1 mmHg
- Accuracy: ±2% or ±1 mmHg, whichever is greater (without sensor)
- Sensitivity: 5uV/mmHgN
- Impedance range: 300 to 3000
C.O. (Optional)
- Method: Thermodilution
- Range: C.O.: 0.1 to 20Umin
- TB: 23 to 43’C
- T1: 0 to 27’C
- Accuracy : C.0.:±5% or ±0.1Umin, whichever is greater
- TB, T1: ±0.1 ‘C (without sensor)
Phasein ISA
- SidestreamC02 (Optional)
- Warm-up time: Full accuracy within 10 seconds
- Sampling flow rate: 50ml/min (+/-10ml/min)
- Accuracy: ± (0.2 % + 2 % of the reading)
- Measurement Range: 0 -15%
- Rise time: 200ms, typical at 50ml/min flow rate
- Total response time: within 3 seconds (with 2 m Nomoline
sampling line)
- AWRR Range: 0-150bpm
- AWRR Accuracy: ±1 breath
Phasein IRMA
- Mainstream C02 (Optional)
- Measurement Range: 0 -15%
- Warm-up time: Full accuracy within 10 seconds
- Accuracy: ± (0.2 % + 2 % of the reading)
- AWRR Range: 0-150bpm
- AWRR Accuracy: ±1 breath
Phasein Multi-gas
(Optional)
- Gas: C02, N20,HAL, ISO, ENF, SEV, DES with automatic identification
- Warm-up time: Full accuracy within 20 seconds for IRMA AX+
- C02 Accuracy : 0-1 0%: ± (0.2 % + 2 % of the reading)
- 10-15%: ± (0.3% + 2% of the reading)
- N20Accuracy: 0-1 00%:± (2% + 2% of the reading)
- HAL, ISO, ENF: 0-8%: ± (0.15% +5% of the reading)
- SEV: 0-10%:± (0.15% +5% of the reading)
- DES:0-22%: ± (0. 15 % +5 % of the reading)
- Agent identification time:< 20s (typical < 10s)
- AWRR range: 0-150bpm
- AWRR accuracy: +/-1 bpm
- Apnea time: 20s, 25s, 30s, 35s,40s
Operation Environment
- Power: AC100-250V, 50/60Hz
- Temperature: 0 -40″C
- Humidity: 15-85%
- Patient Range: Adult, Pediatric, Neonate