Interacoustics

Interacoustics Titan Tympanometer with Screening Impedance

Interacoustics Titan Tympanometer with Screening Impedance may not be in stock. Please call us for ETA before purchasing.

$6,999.00 ex GST

($7,698.90 inc GST)

Customise your Titan for screening, diagnostic and advanced clinical testing. Match the modules with your current needs and upgrade when your challenges change.

The titan delivers Impedance, ABRIS, OAE and the revolutionary Wideband Tympanometry.

Built for the Future

The Titan is a modular platform designed to adapt to your clinical needs, combining handheld flexibility with comprehensive testing options. It supports screening, diagnostic, and advanced clinical assessments, all in one compact system. Built with the future in mind, its software modules are designed based on feedback from experts and include the latest technology for lasting value. Features are developed in sync with your changing needs and contain the latest technologies making the Titan a future-safe investment.

Warranty Information

Device - 2 Years. Accessories - 90 days.

Customise your Titan for screening, diagnostic and advanced clinical testing. Match the modules with your current needs and upgrade when your challenges change.

The titan delivers Impedance, ABRIS, OAE and the revolutionary Wideband Tympanometry.

Built for the Future

The Titan is a modular platform designed to adapt to your clinical needs, combining handheld flexibility with comprehensive testing options. It supports screening, diagnostic, and advanced clinical assessments, all in one compact system. Built with the future in mind, its software modules are designed based on feedback from experts and include the latest technology for lasting value. Features are developed in sync with your changing needs and contain the latest technologies making the Titan a future-safe investment.

A Preview of the Benefits

  • High resolution colour display
  • Patient-centred testing through multiple probe and transducer configurations
  • Handheld and PC mode for full flexibility
  • Easy to use even with minimal technical understanding
  • Supreme usability through storage of calibration values in probe and ID transducers

Easy Handling

From standard screening to advanced diagnostics, the Titan is created with superior usability in mind. From pre-set protocols to customized settings, you will benefit from intuitive interfaces and a professional design.

Tympanometry

Your multi-tasking business partner: Titan is available in a screening, diagnostic or clinical version. It features standard tympanometry, ipsilateral and contralateral acoustic reflexes, reflex decay and reflex latency, as well as tree Eustachian tube function tests.

Tympanometry through advanced technologies: "endless airflow", pressure control technology, high resolution recordings and an intelligent pump system with an adaptive speed control around the tympanic peak.

Titan comes with:

  • Three eustachain tube function tests: intact, perforated and patulous
  • Ipsi and contra acoustic reflexes: quick screenings at a single intensity or fast threshold searches
  • Reflex decay: Ipsilateral as well as contralateral stimulation
  • Reflex latency: Detailed investigation at the onset of the reflex
  • Optional high frequency probe tones: (678, 800 and 1000Hz)
  • Shoulder unit and probe indicator LED: for ease of use and visual feedback of status
Wideband Tympanometry (WBT)

WBT enhances middle ear diagnostics by providing multiple tympanograms from a single sweep, delivering a comprehensive 3D image of ear function across various frequencies and pressures.

Efficient Multi-Frequency Testing
Quickly assess middle ear performance across different frequencies with just one click, saving time while gaining detailed results.

Enhanced Diagnostics
Combining WBT with OAE or ABR fills diagnostic gaps, improving the identification of conductive issues.

Clear 3D Graphs
Absorbance is displayed in a 3D graph, simplifying diagnostic interpretation with easy-to-read data.

No Extra Skills Needed
WBT is user-friendly and intuitive, with overlaid normative data to assist in differential diagnosis.

Interacoustics Titan Tympanometer with Screening Impedance 3D Tympanometric Data. Shop now at Zone Medical.
Automated ABR in Seconds

Automated ABR Module
The automated ABR module uses the CE-Chirp® stimulus to cut test times by up to 50%. With a clear display, HiTrack compatibility, and customizable protocols, the Titan ensures fast and accurate testing. Simply press "START" after patient setup, and the system delivers a pass/refer result in minimal time, offering 99.9% sensitivity and over 96% specificity.

CE-Chirp® Stimulus Family
This advanced stimulus compensates for cochlear travel time, producing response amplitudes up to twice as large as standard clicks.

DPOAE and TEOAE

The OAE modules provide specialized tools for diagnostic OAE assessment and newborn hearing screening. The screening version offers speed, precision, and noise management, ideal for infant tests, while the clinical version delivers maximum flexibility for detailed evaluations with customizable protocols. Both versions can perform pressurized OAE measurements, useful for testing children with middle ear conditions.

Screening Highlights

  • DP range 0.5-6 kHz
  • TE range
  • 1-4.5 kHz (60-84 dB SPL)
  • Customisable PASS/REFER criteria
  • Bayesian weighted averaging
  • Noah and Hitrack compatibility
  • 266 Hz tympanometry
  • Pressurised OAE (optional)

Clinical Highlights

  • DP range 0.5-10 kHz
  • TE range 0.5-5.5 kHz (30-90 dB SPL)
  • Fully customisable protocols
  • Manually controlled test time
  • Unlimited test points
  • Bayesian weighted averaging
  • Noah and Hitrack compatibility
  • DP input/output test
  • 266 Hz tympanometry
  • Operate from Titan or PC
  • Pressurised OAE

    Payment & Security

    Payment methods

    • American Express
    • Apple Pay
    • Google Pay
    • Mastercard
    • Shop Pay
    • Union Pay
    • Visa

    Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

    Interacoustics Titan Tympanometer with Screening Impedance. Shop now at Zone Medical.
    Interacoustics

    Interacoustics Titan Tympanometer with Screening Impedance

    $6,999.00 ex GST

    ($7,698.90 inc GST)

    Customise your Titan for screening, diagnostic and advanced clinical testing. Match the modules with your current needs and upgrade when your challenges change.

    The titan delivers Impedance, ABRIS, OAE and the revolutionary Wideband Tympanometry.

    Built for the Future

    The Titan is a modular platform designed to adapt to your clinical needs, combining handheld flexibility with comprehensive testing options. It supports screening, diagnostic, and advanced clinical assessments, all in one compact system. Built with the future in mind, its software modules are designed based on feedback from experts and include the latest technology for lasting value. Features are developed in sync with your changing needs and contain the latest technologies making the Titan a future-safe investment.

    A Preview of the Benefits

    Easy Handling

    From standard screening to advanced diagnostics, the Titan is created with superior usability in mind. From pre-set protocols to customized settings, you will benefit from intuitive interfaces and a professional design.

    Tympanometry

    Your multi-tasking business partner: Titan is available in a screening, diagnostic or clinical version. It features standard tympanometry, ipsilateral and contralateral acoustic reflexes, reflex decay and reflex latency, as well as tree Eustachian tube function tests.

    Tympanometry through advanced technologies: "endless airflow", pressure control technology, high resolution recordings and an intelligent pump system with an adaptive speed control around the tympanic peak.

    Titan comes with:

    Wideband Tympanometry (WBT)

    WBT enhances middle ear diagnostics by providing multiple tympanograms from a single sweep, delivering a comprehensive 3D image of ear function across various frequencies and pressures.

    Efficient Multi-Frequency Testing
    Quickly assess middle ear performance across different frequencies with just one click, saving time while gaining detailed results.

    Enhanced Diagnostics
    Combining WBT with OAE or ABR fills diagnostic gaps, improving the identification of conductive issues.

    Clear 3D Graphs
    Absorbance is displayed in a 3D graph, simplifying diagnostic interpretation with easy-to-read data.

    No Extra Skills Needed
    WBT is user-friendly and intuitive, with overlaid normative data to assist in differential diagnosis.

    Interacoustics Titan Tympanometer with Screening Impedance 3D Tympanometric Data. Shop now at Zone Medical.
    Automated ABR in Seconds

    Automated ABR Module
    The automated ABR module uses the CE-Chirp® stimulus to cut test times by up to 50%. With a clear display, HiTrack compatibility, and customizable protocols, the Titan ensures fast and accurate testing. Simply press "START" after patient setup, and the system delivers a pass/refer result in minimal time, offering 99.9% sensitivity and over 96% specificity.

    CE-Chirp® Stimulus Family
    This advanced stimulus compensates for cochlear travel time, producing response amplitudes up to twice as large as standard clicks.

    DPOAE and TEOAE

    The OAE modules provide specialized tools for diagnostic OAE assessment and newborn hearing screening. The screening version offers speed, precision, and noise management, ideal for infant tests, while the clinical version delivers maximum flexibility for detailed evaluations with customizable protocols. Both versions can perform pressurized OAE measurements, useful for testing children with middle ear conditions.

    Screening Highlights

    • DP range 0.5-6 kHz
    • TE range
    • 1-4.5 kHz (60-84 dB SPL)
    • Customisable PASS/REFER criteria
    • Bayesian weighted averaging
    • Noah and Hitrack compatibility
    • 266 Hz tympanometry
    • Pressurised OAE (optional)

    Clinical Highlights

    • DP range 0.5-10 kHz
    • TE range 0.5-5.5 kHz (30-90 dB SPL)
    • Fully customisable protocols
    • Manually controlled test time
    • Unlimited test points
    • Bayesian weighted averaging
    • Noah and Hitrack compatibility
    • DP input/output test
    • 266 Hz tympanometry
    • Operate from Titan or PC
    • Pressurised OAE
      View product