MIR Spiro Software Platinum Card Subscription
MIR Spiro Software Platinum Card Subscription - 1 Year may not be in stock. Please call us for ETA before purchasing.
Couldn't load pickup availability
The MIR Spiro Software is a cutting-edge solution designed to enhance spirometry and oximetry assessments. Seamlessly integrating with EMR/EHR systems, it is compliant with the latest ATS/ERS guidelines and is available for both MacOS and Windows, making it accessible on desktop and laptop platforms.
Key Features:
Advanced Spirometry Analysis:
- Session Summary: Includes FVC, SVC, MVV, and FVC History for session comparisons.
- Editing Tools: Set Best Test, Disable/enable/delete/retrieve tests, and configure additional parameters for customized display.
Advanced Oximetry Analysis:
- Specific Analyses: Includes Walk Test (6MWT), Sleep test, and Holter for 24h saturation with adjustable titration.
Data Delivery Service (DDS):
- Integration: Facilitates data delivery from the local database to third-party platforms and EMR/EHR systems.
Privacy and Security:
- Multi-user Mode: Allows each MIR Spiro user to log in with their account.
- Anonymisation Feature: Provides options to print, manage patient lists, and export data securely.
EMR/EHR Integration:
- Interoperability: Optimizes workflows and data exchange with EMR/EHR through standards like HL7, FHIR (Json), GDT, DICOM, and eXchange Protocol.
Complete and Customizable Prints:
- Formats: Supports ATS2019, Winspiro classic, and NIOSH-OSHA formats.
Data Import:
- Device Compatibility: Allows importing tests from MIR professional devices.
Virtual Assistant:
- Diagnostic Support: Displays the relationship between spirometry interpretation (obstruction/restriction) and the flow/volume curve shape.
Pediatric Incentives:
- Real-time Animation: Improves patient collaboration during tests with animations based on Flow and Volume algorithms.
Powerful Data Sharing Capabilities:
- Formats: Export in various formats such as ATS formatted file, .mirX, Proprietary MIR Spiro format, .csv (Excel), .pdf, .hl7, .gdt, and dicom.
Connectivity:
- Device Compatibility: Works with all MIR professional devices via USB and Bluetooth Low Energy (BLE ≥4.0).
Reference Equations:
- Selection: Choose from a list of 18 primary and secondary authors, including GLI, NHANES, ERS, KNUDSON, and more.
Pictograms for zScore & LLN:
- Display: Shows LLN, zScore, and pictograms for PRE & POST score for FVC, FEV1, and FEV1/FVC.
Deleted Data Recovery:
- One-Click Retrieval: Recover the entire deleted spirometry or oximetry session.
Cloud Service for Updates:
- Software and Firmware: Provides updates for software and firmware via the cloud.
Log of Critical Operations and Errors:
- Tracking: Advanced system for logging critical operations and errors.
Additional Platinum Features:
Data Delivery Service:
- Unrestricted Data Exchange: Seamlessly exchange data between MIR Spiro and external platforms.
Unlimited Access to Extra Content and Updates:
- Innovation: Stay updated with the latest advancements and features.
Platinum Customer Support:
- Live Support: Access live support from a MIR operator anytime, anywhere, including one free session of remote video assistance.
Experience the full potential of MIR Spiro Software with the Platinum subscription plan, offering unmatched diagnostic capabilities, ease of use, and seamless integration with your medical records system. Get ready to elevate your clinical assessments and decision-making process with this comprehensive spirometry and oximetry solution.
Basic | Platinum | ||
TEST | FVC Pre/Post | ✔ | ✔ |
VC Pre/Post | ✔ | ✔ | |
Oximetry Spot | ✔ | ✔ | |
MVV Pre/Post | ✘ | ✔ | |
Oximetry 6MWT | ✘ | ✔ | |
Oximetry Sleep | ✘ | ✔ | |
PATIENT MANAGEMENT | New patient/Patient List | ✔ | ✔ |
Patient Search | ✔ | ✔ | |
Patient Session Summary | ✘ | ✔ | |
Patient Risk factors/Symptoms | ✔ | ✔ | |
Test cronology comparison | ✘ | ✔ | |
Worklist | ✘ | ✔ | |
PRINTOUTS | FVC Printout STD | ✔ | ✔ |
FVC Printout ATS 2019 | ✔ | ✔ | |
FVC Printout STD NIOSH/OSHA | ✘ | ✔ | |
Oximetry Printout | ✘ | ✔ | |
Calibration Printout | ✘ | ✔ | |
VC Printout | ✘ | ✔ | |
Quality Grade Printout | ✔ | ✔ | |
DATA MANAGEMENT | Data sharing/Interoperability | ✔ | ✔ |
Data import from Legacy db | ✔ | ✔ | |
Data Import from third parties sfw db | ✔ | ✔ | |
Data Export in Excel/csv/ATS/HL7/GDT | ✘ | ✔ | |
Data Recovery | ✘ | ✔ |
Tests supported | Spirometry |
Oximetry | |
Supported spirometry tests | FVC (Forced Vital Capacity) PRE and POST bronchodilator |
SVC (Slow Vital Capacity) PRE and POST bronchodilator | |
MVV (Voluntary Maximum Ventilation) PRE and POST bronchodilator | |
Supported oximetry tests | Spot oximetry Six-minute walk test Sleep oximetry Oximetry holter (24 hours) |
Supported languages | Chinese (China), Chinese (Taiwan), Czech (Czechia), Dutch (Netherlands), English (United Kingdom), English (United States), French (France), French (Belgium), Georgian (Georgia), German (Germany), Hungarian (Hungary), Italian (Italy), Japanese (Japan), Latvian (Latvia), Polish (Poland), Portuguese (Portugal), Romanian (Romania), Russian (Russia), Spanish (Spain), Swedish (Sweden), Turkish (Turkey), Ukrainian (Ukraine) |
FVC parameters | FVC, FEV1, PEF, FEF75, FEF2575, FET, FEV1/FVC, FEV6, FEV1/FEV6, FEF25, FEF50, FIVC, FEV1/VC, ELA, MVV (cal), Time to PEF, FEV05, FEV05/FVC, FEV075, FEV075/FVC, FEF7585, Extr. Vol, FEV3, FIV1, FIV1/FIVC, PIF, FEV3/FVC, PIF, FEV2, FEV2/FVC, FIF25, FIF50, FIF75, R50, FEV1/PEF (EI), FEV1/FEV05 (RFEV), RR, tl, tE, TV/tl, tl/Ttot, te/ti, VTTI |
VC Parameters | VC, EVC, IVC, IC, VC, ERV, IRV, TV, VE |
MVV parameters | MV, MVV |
Oximetry parameters | |
Spot test | Sp02 [Baseline, Min, Max, Mean], Pulse frequency [Baseline, Min, Max, Mean], T40, T120,T90,T89, T88, T87, Index [12s], Sp02 Events, Pulse frequency Events [Bradycardia, Tachycardia], Time-Tot, Measured-Time |
Walk test | 02-Gap, Estimated distance, Distance travelled, Estimated distance [Min, Standard], TA2% [Sp02=2%],TA4% [ASp02≥4%], Time [Rest, Walk, Recovery], Desaturation area/ Distance Optional data entry: Borg dyspnea [Baseline, End, Change], Borg fatigue [Baseline, End, Change], Blood pressure [Diastolic Systolic], Oxygen administered, Sp02/BPM (Med. Min. Max. In. Fin.), T90,T89,T88,T87, Sp02/BPM Events. |
Sleep tests | Sp02 events, Pulse frequency events [Bradycardia, Tachycardia] Desaturation index (ODI), Desaturation [Mean value, Mean duration Maximum duration, Peak Nadir], ASp02 [Minimum drop, Maximum drop], Total pulse changes, Pulse frequency index, NOD time (4%, 89%, 90%), Sp02/BPM (Med. Min. Max. In. Fin.) |
Equations for the calculation of theoretical Values | Barcelona Zapletal; ECSC 1971; Chile 2014; Crapo-Bass Knudson; ERS ECCS Knudson; ERS ECCS Zapletal; Forche 2001 Knudson; GLI; Hedenström Solymar, Hong Kong; Thoracic Society; Japan Respiratory Society; Knudson; Nhanes; Pereira; Perez Padilla; Pneumobill Knudson; South Korean (Dél-koreai); Thailand (Thaiföld) |
Supported devices |
|
System requirements | |
Windows |
|
MacOS |
|
*Spirolab, Minispir, Minispir Light, Spirodoc, Spirobank II with Bluetooth Smart, Spirobank II Advanced, and Spirobank II BASIC connect to MIR Spiro software by USB cable. Spirobank II Smart connects to MIR Spiro software by both USB cable and Bluetooth Low Energy.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.