Northern  |  SKU: NAMPXSRB

Northern Aquarius Plus Patient Monitor with EtCo2, ECG & Touchscreen REFURBISHED

$2,999.00 GST Exempt

Vitals Monitor Features:

  • Adult SpO2 Sensor
  • 3 Lead ECG
  • Surface Temp
  • Li-ion Battery (up to 10 hrs)
  • Economic Patient Monitor
  • 8” colour TFT LCD Screen (touch screen option)
  • Portable, ergonomic, light weight, sturdy design
  • Suitable for adult, pediatric & neonatal patients
  • Flexible parameters configuration for different clinical environments
  • Standard Configuration 3 Lead ECG, NIBP, Spo2, Temp
  • Spot-check and continuous monitoring mode with alarms
  • Graphical & tabular trend review with customisable size & colour settings
  • Rechargeable Li-ion Battery (up to 10 hours)
  • 48 hours holographic wave review for each patient
  • Comes with EtCO2

*Stand not included

Optional
Thermal printer, Wall Mount, Multigas, Nellcor/Masimo, IBP, Bar Code Scan
Wired or Wireless CMS (Central Monitoring System)


The Northern Aquarius plus is our most popular patient monitor bringing all major parameters to a convenient little monitor. Includes NIBP, SpO2, ECG, Surface Temp, PR, EtCo2  and Touchscreen. Suitable for Adult, Pediatric and Neonate patients.

Featuring a suite of essential parameters and a user-friendly 8” colour TFT LCD touchscreen, the Northern Aquarius Plus is a reliable, economic choice for healthcare facilities seeking accuracy, portability, and ease of use.

Key Features:

  • Broad Patient Compatibility: Suitable for adult, paediatric, and neonatal patients, ensuring versatile use across different healthcare scenarios.
  • Comprehensive Monitoring: Standard configuration includes 3 Lead ECG, NIBP, SpO2, and Temp, providing critical vitals at a glance.
  • High-Quality Display: 8” colour TFT LCD screen with touchscreen capability for intuitive navigation and data entry.
  • Extended Battery Life: Equipped with a Li-ion battery offering up to 10 hours of operation, ideal for continuous monitoring.
  • Portable Design: Ergonomic, lightweight, and sturdy, making it easy to move and position where needed.
  • Advanced Data Analysis: Spot-check and continuous monitoring modes with alarms, plus graphical and tabular trend review for detailed patient data analysis.
  • Customisable Parameters: Flexible configuration for different clinical environments, with optional features including Thermal printer, Wall Mount, EtCO2, Multigas, and more for enhanced functionality.

 

Display
8” color TFT LCD Screen,resolution: 800 x 600

ECG
Lead type
3-lead:l, II, Ill
S· lead:l, II, lll,aVR, a VI., aVF, V

Display sensitivity:
2.5mm;mv (x0.25), Smm;mv (x0.5), 10mm;mv (x1.0),
20mm;mv {x2.0)
Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

Bandwidth
Diagnostic mode: 0.05Hz-100Hz
Monitor mode: 0.5Hz-40Hz
Surgery mode: 1Hz-20Hz
Strong filter mode: 5Hz-20Hz

CMRR>100dB
Notch: 50/60Hz notch filter can be set to on or off
Differential input impedance> SMO
Electrode polarization voltage range: ±400mV
Baseline recovery time<3s after defibrillation {in monitor and
surgery mode)
Calibration signal:1mV (peak – peak), accuracy ±3%

RESP
Measurement method : Thoracic electrical bio1 pedance
Measuring lead: Lead I, II
Wave gain: x0.25, xO.S, x 1, x2
Respiratory impedance range: 0.5 ·50
Baseline impedance: 500-40000
Gain: 10 grades
Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s

TEMP
Measurement method: Thermistor
Measuring range: 5- SO’C (41-122’F)
Resolution: 0.1’C
Measurement accuracy: ±0.1’C

Printing (optional)
Built-in,Thermal dot array
Horizontal resolution :16 dots/mm (25 mm/s paper speed)
Vertical resolution:8 dots/mm
Paper speed:25 mm/s, 50 mm/s
Number of waveform channels:3

NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20-40s
Measurement type: Systolic, Diastolic,Mean
Measurement range {mmHg)

Range of Systolic pressure:
Adult 40-270
Pediatric 40-230
Neonatal 40-135

Range of Diastolic pressure:
Adult 10-210
Pediatric 10-150
Neonatal 10-100

Range of Mean pressure:
Measurement accuracy
Adult 20-230
Pediatric 20-165
Neonatal 20-110

Maximum average error: ±SmmHg
Maximum standard deviation: 8mmHg
Resolution: 1 mmHg
interval:1 ,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480minutes
Overpressure protection: Software and hardware,double
safety protection
Cuff pressure range: 0-280mmHg

Northern SpO2
Measurement range : 0·1 00%
Resolution: 1%
Accuracy: ±2% ( 70-100%, Adult/Pediatric);
±3% { 70-100% , Neonate);
0 -69%,unspecified
Refreshing Rate: 1 s

Masimo SpO2 (optional)
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2% { 70-100% , Adult/Pediatric,non-motion,low prelusion);
±3% { 70-100%, Neonate,non-motion);
±3% ( 70-100% , motion);
0-69%,unspecified
Refreshing Rate: 1

Infrared Ear thermometer (optional)
Diplayed range: 34- 42.2’C {93.2-108 F’)
Operation ambient temperature range: 10-40’C{ 50-104’F)
Accuracy for displayed temperature range:
~35’C{ 95.9’F) -s42.2’C{ 107.6’F) range ±0.2’C{ 0.4’F)
< 35’C ( 95.9’F ) – ~34’C { 93.2’F) range ±0.3’C{ O.S’F)

Phasein IRMA Sidestream CO2 (optional)
Warm·up time: Full accuracy within 10 seconds
Sampling flow rate: SOml/min(+/·10/min)
Accuracy:±(0.2%+2% of the reading)
Measurement Range: 0 ·15%
Rise time: 200ms,typical at SOml/min flow rate
Total response time:
within 3 seconds(with 2m Momoline sampling line)
AWRR Range: 0·150bpm
AWRR Accuracy:±1 breath

Phasein IRMA Mainstream CO2 (optional)
Measurement Range: 0 ·15%
Warm-up time: Full accuracy within 10 seconds
Accuracy:±(0.2%+2% of the reading}
AWRR Range: 0-150bpm
AWRR Accuracy·+ 1 breath

Operating Environment
Phasein IRMA MAinstream CO2
Power: AC-=250, 50/60Hz
Temperature: 0-40C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Northern

Northern Aquarius Plus Patient Monitor with EtCo2, ECG & Touchscreen REFURBISHED

$2,999.00 GST Exempt

The Northern Aquarius plus is our most popular patient monitor bringing all major parameters to a convenient little monitor. Includes NIBP, SpO2, ECG, Surface Temp, PR, EtCo2  and Touchscreen. Suitable for Adult, Pediatric and Neonate patients.

Featuring a suite of essential parameters and a user-friendly 8” colour TFT LCD touchscreen, the Northern Aquarius Plus is a reliable, economic choice for healthcare facilities seeking accuracy, portability, and ease of use.

Key Features:

  • Broad Patient Compatibility: Suitable for adult, paediatric, and neonatal patients, ensuring versatile use across different healthcare scenarios.
  • Comprehensive Monitoring: Standard configuration includes 3 Lead ECG, NIBP, SpO2, and Temp, providing critical vitals at a glance.
  • High-Quality Display: 8” colour TFT LCD screen with touchscreen capability for intuitive navigation and data entry.
  • Extended Battery Life: Equipped with a Li-ion battery offering up to 10 hours of operation, ideal for continuous monitoring.
  • Portable Design: Ergonomic, lightweight, and sturdy, making it easy to move and position where needed.
  • Advanced Data Analysis: Spot-check and continuous monitoring modes with alarms, plus graphical and tabular trend review for detailed patient data analysis.
  • Customisable Parameters: Flexible configuration for different clinical environments, with optional features including Thermal printer, Wall Mount, EtCO2, Multigas, and more for enhanced functionality.

 

Display
8” color TFT LCD Screen,resolution: 800 x 600

ECG
Lead type
3-lead:l, II, Ill
S· lead:l, II, lll,aVR, a VI., aVF, V

Display sensitivity:
2.5mm;mv (x0.25), Smm;mv (x0.5), 10mm;mv (x1.0),
20mm;mv {x2.0)
Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

Bandwidth
Diagnostic mode: 0.05Hz-100Hz
Monitor mode: 0.5Hz-40Hz
Surgery mode: 1Hz-20Hz
Strong filter mode: 5Hz-20Hz

CMRR>100dB
Notch: 50/60Hz notch filter can be set to on or off
Differential input impedance> SMO
Electrode polarization voltage range: ±400mV
Baseline recovery time<3s after defibrillation {in monitor and
surgery mode)
Calibration signal:1mV (peak – peak), accuracy ±3%

RESP
Measurement method : Thoracic electrical bio1 pedance
Measuring lead: Lead I, II
Wave gain: x0.25, xO.S, x 1, x2
Respiratory impedance range: 0.5 ·50
Baseline impedance: 500-40000
Gain: 10 grades
Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s

TEMP
Measurement method: Thermistor
Measuring range: 5- SO’C (41-122’F)
Resolution: 0.1’C
Measurement accuracy: ±0.1’C

Printing (optional)
Built-in,Thermal dot array
Horizontal resolution :16 dots/mm (25 mm/s paper speed)
Vertical resolution:8 dots/mm
Paper speed:25 mm/s, 50 mm/s
Number of waveform channels:3

NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20-40s
Measurement type: Systolic, Diastolic,Mean
Measurement range {mmHg)

Range of Systolic pressure:
Adult 40-270
Pediatric 40-230
Neonatal 40-135

Range of Diastolic pressure:
Adult 10-210
Pediatric 10-150
Neonatal 10-100

Range of Mean pressure:
Measurement accuracy
Adult 20-230
Pediatric 20-165
Neonatal 20-110

Maximum average error: ±SmmHg
Maximum standard deviation: 8mmHg
Resolution: 1 mmHg
interval:1 ,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480minutes
Overpressure protection: Software and hardware,double
safety protection
Cuff pressure range: 0-280mmHg

Northern SpO2
Measurement range : 0·1 00%
Resolution: 1%
Accuracy: ±2% ( 70-100%, Adult/Pediatric);
±3% { 70-100% , Neonate);
0 -69%,unspecified
Refreshing Rate: 1 s

Masimo SpO2 (optional)
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2% { 70-100% , Adult/Pediatric,non-motion,low prelusion);
±3% { 70-100%, Neonate,non-motion);
±3% ( 70-100% , motion);
0-69%,unspecified
Refreshing Rate: 1

Infrared Ear thermometer (optional)
Diplayed range: 34- 42.2’C {93.2-108 F’)
Operation ambient temperature range: 10-40’C{ 50-104’F)
Accuracy for displayed temperature range:
~35’C{ 95.9’F) -s42.2’C{ 107.6’F) range ±0.2’C{ 0.4’F)
< 35’C ( 95.9’F ) – ~34’C { 93.2’F) range ±0.3’C{ O.S’F)

Phasein IRMA Sidestream CO2 (optional)
Warm·up time: Full accuracy within 10 seconds
Sampling flow rate: SOml/min(+/·10/min)
Accuracy:±(0.2%+2% of the reading)
Measurement Range: 0 ·15%
Rise time: 200ms,typical at SOml/min flow rate
Total response time:
within 3 seconds(with 2m Momoline sampling line)
AWRR Range: 0·150bpm
AWRR Accuracy:±1 breath

Phasein IRMA Mainstream CO2 (optional)
Measurement Range: 0 ·15%
Warm-up time: Full accuracy within 10 seconds
Accuracy:±(0.2%+2% of the reading}
AWRR Range: 0-150bpm
AWRR Accuracy·+ 1 breath

Operating Environment
Phasein IRMA MAinstream CO2
Power: AC-=250, 50/60Hz
Temperature: 0-40C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate

View product